FAST VALVE RESPONSE

Pneumatic rotary control valves for fast valve response.

Fast valve response starts with the actuation design.

A compact vane design and stored-air fail-safe support rapid quarter-turn movement.

Stroke time (seconds per direction)

Actuator modelStandard portsStandard product · Standard lead timeStandard ports + QEVSimple add-on · Minimal added cost · Standard lead timeFactory custom ports + QEVCustom modification · Custom pricing · Longer lead timeRepresentative resilient-seated butterfly valve size
EVA04110.24–0.27Not publishedNot publishedDouble-acting: 3–4″ Fail-safe: 2–3″
EVA05140.36–0.390.10–0.15Not publishedDouble-acting: 4–6″ Fail-safe: 3–4″
EVA07170.45–0.470.20–0.25Not publishedDouble-acting: 6–8″ Fail-safe: 5–6″
EVA10220.59–0.600.48Not publishedDouble-acting: 8–12″ Fail-safe: 6–10″
EVA12270.75–0.840.5–0.7Not publishedDouble-acting: 12–16″ Fail-safe: 10–12″
EVA14361.34–1.470.650.54–0.57Double-acting: 16–20″ Fail-safe: 12–18″
EVA16463.30–3.411.100.70Double-acting: 22–26″ Fail-safe: 18–22″

Notes

Testing: Cv 1.8, standard for Easytork solenoid and pilot valves; on/off operation, no load, at 80 psi air supply.

Representative resilient-seated sizing: 100 psi valve differential and 60–100 psi actuator air supply.

Gas-generation skids

For switching duties in selected PSA, VSA and VPSA systems. Match the travel profile to the process sequence.

Ground-test systems

For quarter-turn fluid-control duties where response time is part of the test requirement.

Public Easytork gallery collage showing actuators installed among piping on a rocket multi-engine test stand.
EVA1227 demonstration

Third-party valve cycle tests.

On/off and modulating configurations with 10-inch and 6-inch butterfly valves.

Watch the third-party valve cycle tests

The modulating test omits NTV; the 10-inch modulating setup uses double-acting actuation with a QEV. Cycling demonstrations do not establish a fast fail-safe stroke for every shown configuration.

WHY EASYTORK?

Why Easytork delivers fast response

Actuation drives valve response.

Optimized direct rotary vane design

Efficient rotary vane motion converts air pressure directly into rotary torque through compact working chambers.

Integrated stored-air fail-safe

Stored-air fail-safe eliminates the return-spring load that drives inefficient actuator upsizing. The integrated reservoir supplies energy for the configured return stroke.

Explore the engineering behind physical stroke time

Air volume, control flow, piping and valve load all shape the stroke time.

CONTACT EASYTORK

Tell us your required
stroke time.

Start with your headache.

Tell us about your control valve application and what you’d like to improve: reliability, speed, size, weight or low-pressure operation.

Tell us your required stroke time+1 (314) 266-6880