Gas-generation skids
For switching duties in selected PSA, VSA and VPSA systems. Match the travel profile to the process sequence.
Fast valve response starts with the actuation design.
A compact vane design and stored-air fail-safe support rapid quarter-turn movement.
| Actuator model | Standard portsStandard product · Standard lead time | Standard ports + QEVSimple add-on · Minimal added cost · Standard lead time | Factory custom ports + QEVCustom modification · Custom pricing · Longer lead time | Representative resilient-seated butterfly valve size |
|---|---|---|---|---|
| EVA0411 | 0.24–0.27 | Not published | Not published | Double-acting: 3–4″ Fail-safe: 2–3″ |
| EVA0514 | 0.36–0.39 | 0.10–0.15 | Not published | Double-acting: 4–6″ Fail-safe: 3–4″ |
| EVA0717 | 0.45–0.47 | 0.20–0.25 | Not published | Double-acting: 6–8″ Fail-safe: 5–6″ |
| EVA1022 | 0.59–0.60 | 0.48 | Not published | Double-acting: 8–12″ Fail-safe: 6–10″ |
| EVA1227 | 0.75–0.84 | 0.5–0.7 | Not published | Double-acting: 12–16″ Fail-safe: 10–12″ |
| EVA1436 | 1.34–1.47 | 0.65 | 0.54–0.57 | Double-acting: 16–20″ Fail-safe: 12–18″ |
| EVA1646 | 3.30–3.41 | 1.10 | 0.70 | Double-acting: 22–26″ Fail-safe: 18–22″ |
Testing: Cv 1.8, standard for Easytork solenoid and pilot valves; on/off operation, no load, at 80 psi air supply.
Representative resilient-seated sizing: 100 psi valve differential and 60–100 psi actuator air supply.
For switching duties in selected PSA, VSA and VPSA systems. Match the travel profile to the process sequence.
For quarter-turn fluid-control duties where response time is part of the test requirement.

On/off and modulating configurations with 10-inch and 6-inch butterfly valves.
Watch the third-party valve cycle tests
The modulating test omits NTV; the 10-inch modulating setup uses double-acting actuation with a QEV. Cycling demonstrations do not establish a fast fail-safe stroke for every shown configuration.
Actuation drives valve response.
Efficient rotary vane motion converts air pressure directly into rotary torque through compact working chambers.
Stored-air fail-safe eliminates the return-spring load that drives inefficient actuator upsizing. The integrated reservoir supplies energy for the configured return stroke.
Air volume, control flow, piping and valve load all shape the stroke time.
Tell us about your control valve application and what you’d like to improve: reliability, speed, size, weight or low-pressure operation.
Tell us your required stroke timeinfo@easytork.com+1 (314) 266-6880