1. Existing linear arrangement
The regulated low-pressure circuit serves the controller and linear package.
LOW-PRESSURE CONTROL
Keep the circuit you have. Add the rotary valve benefits your application needs.
WHAT YOU KEEP
Controller: P/P liquid-level controller
Where the automatic catcher and motor valve share a low-pressure supply, the catcher’s pressure limit constrains actuator selection. Keep that circuit and catcher in place while replacing the linear motor-valve package with an Easytork rotary alternative.
Retain the pneumatic liquid-level controller and its low-pressure arrangement for compatible snap service. Easytork brings the rotary valve, actuator and controls together, without the separate higher-pressure actuator supply shown in the alternative arrangement.
The regulated low-pressure circuit serves the controller and linear package.
This design adds an actuator-supply branch, regulator, pilot valve, and airline modifications.
Keep the existing low-pressure controller circuit and reconnect the output airline to the Easytork package.
Keep the existing low-pressure control circuit with a rotary package selected for the controller output and required valve duty.
Temperature-control example: the diagrams below show the existing linear package and a rotary alternative for the illustrated temperature-controller circuit.
WHAT YOU GAIN
A suitable full-port ball valve combines high capacity, protected seating and quarter-turn operation for snap-acting liquid dumps.
An unobstructed bore lets discharged liquid pass directly through the fully open valve, with fewer internal turns than conventional globe-style passages.
With suitable ball-and-seat geometry, the sealing surfaces are shielded from direct abrasive flow when fully open and fully closed. Conventional globe-style plugs and seats can remain exposed to the flow when open.
A short, 90-degree stroke suits the open, dump and close sequence. Prompt transitions limit time at a restricted opening when the liquid carries sand.
The pilot valve is the controller and operates in snap-acting service.
Keep your low-pressure air supply with the supplied throttling control valve.
Already using a positioner? Retain the same piping logic.
Direct air-to-spring control? Revise the piping to include the positioner.
Compare the existing linear package with the Easytork rotary package. Both operating states are shown below.
Watch two valve-package demonstrations using approximately 30 psi air supply.
Snap-acting demonstration using approximately 30 psi air supply.
Watch on VimeoSnap-acting demonstration using approximately 30 psi air supply.
Actuator sizing: the current actuator provides sufficient torque for a maximum differential pressure of 2,000 psi at 35 psi air supply. Higher differential pressure requires a larger actuator, within the valve’s pressure rating.
This is an actuator-sizing limit-not the valve’s working-pressure rating or a claim that this video demonstrates operation under 2,000 psi differential pressure.
Watch on VimeoEasytork: field-reversible fail-open or fail-close. Choose the action your application requires.
Download the published low-pressure case study and snap-acting example (PDF)
Easytork brings the valve, actuator, controls and feedback together around your application.
Discuss your packageReview charged supply pressure, usable torque and the required fail action.
Tell us about your control valve application and what you’d like to improve: reliability, speed, size, weight or low-pressure operation.
Package selection depends on valve torque, available pressure, process conditions, and required fail action. For burner or fuel service, review the required shutoff and safety functions.
Discuss my applicationinfo@easytork.com+1 (314) 266-6880