Home/Products & data/NTV NAMUR trip valve
ACTUATION ACCESSORIES

NTV NAMUR trip valve

Add fail-safe operation to positioner-controlled Easytork actuators.

Easytork NAMUR trip valve on a vane actuator.
Easytork NAMUR trip valve on a vane actuator.
Follow the air path

NTV with double-acting positioner

The positioner controls normal travel through the NTV. On supply loss, the NTV routes stored reservoir air for the configured fail stroke.

Airflow schematic

Left: Double-acting positioner
Right: NTV trip valve

Airflow schematic: double-acting positioner on the left, NTV trip valve on the right, with supply, output and reservoir ports.
Open full-size schematic →

NTV airflow in motion

Normal operation, reservoir charging and the configured fail-safe air path.

Watch on Vimeo →
Read the schematic: ports & fail-safe sequence
Two distinct jobs
The double-acting positioner controls valve position during modulating / throttling service. The NTV provides the reservoir fail-safe air path; it does not replace the positioner.
During normal operation
In the schematic, positioner Out 1 connects to NTV port A, and Out 2 to port D. These outputs pass through the NTV to actuator service ports P2 and P4. Dedicated reservoir porting maintains stored pneumatic energy alongside normal positioning.
On loss of air supply
The NTV isolates the stored-air supply and redirects it to drive the actuator to the configured fail position, rather than continuing normal positioner control.

Engineering guide: how the control paths work →

For installation, use the model-specific technical documents and IOM.

How the NTV changes the arrangement

Double-acting arrangement without NTV and fail-safe arrangement with NTV.
Double-acting arrangement without NTV and fail-safe arrangement with NTV.
NTV orientation and clockwise / counter-clockwise fail action.
NTV orientation and clockwise / counter-clockwise fail action.

Position control. Defined fail action.

The NTV connects the actuator, positioner and integral air reservoir for configured fail-safe operation. Use a double-acting positioner with EVA or ECA actuators-both for double-acting service and for fail-safe service with an NTV.

The positioner controls normal travel. On loss of supply air, the NTV routes stored air to drive the actuator in the configured fail direction. Evaluate response at the valve stem →

Use with a positioner

The NTV is universally compatible with any double-acting positioner for modulating duty.

Choose the fail direction

The NTV installation orientation sets clockwise or counter-clockwise fail action. Follow the mounting and piping instructions for the actuator model.

Keep the controls clear

For on/off service, explore the ESV solenoid valve or an EPV pilot arrangement with a suitable third-party solenoid.

Connect the system

Connect the command signal to the positioner and supply air to the specified Easytork arrangement.

Installation and operation

Control actuator and NTV overview

Watch on YouTube →

NTV installation procedures

Watch on YouTube →
Application support

Bring the duty.
We’ll work through the actuation.

Torque, air supply, operating conditions and the action you need.