Match the accessory.
Verify the interface.
Separate top-work feedback mounting from pneumatic control connections, then choose the ESV, EPV or NTV arrangement for the duty.
Separate the interfaces before choosing the accessories
The connection to the process valve, the top-mounted feedback connection and the pneumatic control connection serve different purposes. A shared standards label does not make them the same interface. Check the drawing for the selected actuator and accessory.
Top work: mounting and motion feedback
Limit switches and positioners use the actuator’s top-work mounting and shaft interface. The mounting pattern locates the accessory; the shaft connection communicates actuator rotation.
AA-series top-work dimensions
In the auxiliary interface drawing, Q is the mounting-pattern length, R is its width, and D is the shaft height above the top-work attachment surface. AA sizes define the mechanical interface for positioners and limit-switch assemblies. Match all three dimensions to the accessory bracket and shaft connection.
| Interface | Q × R × D (mm) | Q × R × D (in) | EVA models |
|---|---|---|---|
| AA0 | 50 × 25 × 15 | 1.97 × 0.98 × 0.59 | EVA-0309 (legacy; no longer sold) |
| AA1 | 80 × 30 × 20 | 3.15 × 1.18 × 0.79 | EVA-0411, EVA-0514, EVA-0717 |
| AA2 | 80 × 30 × 30 | 3.15 × 1.18 × 1.18 | EVA-1022 |
| AA3 | 130 × 30 × 30 | 5.12 × 1.18 × 1.18 | EVA-1227, EVA-1436, EVA-1646, EVA-1646 Tandem |
| AA4 | 130 × 30 × 50 | 5.12 × 1.18 × 1.97 | No EVA model |
| AA5 | 200 × 50 × 80 | 7.87 × 1.97 × 3.15 | No EVA model |
Pneumatic interface: pressure connections and control function
NAMUR pneumatic mounting provides a standardized connection between a solenoid or pilot valve and a rotary actuator. For EVA-0411 through EVA-1436, the valve mounts against the actuator’s mating face and aligned ports 2 and 4 carry air directly between the components. EVA-1646 accepts the solenoid at the mounting pattern but has no integrated port 2/4 passages there; connect its external actuator ports with tubing. VDI/VDE 3845 covers this pneumatic interface as well as separate mechanical interfaces for limit switches and positioners.
Which EVA models have NAMUR mounting?
All seven current EVA sizes listed here have NAMUR accessory mounting: EVA-0411, EVA-0514, EVA-0717, EVA-1022, EVA-1227, EVA-1436 and EVA-1646.
| EVA model | Mounting pattern | Ports 2 & 4 connection (drawing P) |
|---|---|---|
| EVA-0411 | 32 × 24 mm; M5 | 1/8-28 BSPP or 1/8-27 NPT |
| EVA-0514, EVA-0717, EVA-1022, EVA-1227, EVA-1436 | 32 × 24 mm; M5 | 1/4-19 BSPP or 1/4-18 NPT |
| EVA-1646 | 32 × 24 mm; M5 | External ports and tubing required; no integrated ports 2/4 at the mounting face |
Standard NAMUR 5/2 solenoid valves can serve double-acting arrangements: direct integrated port connections on EVA-0411 through EVA-1436, and external tubing on EVA-1646. Reservoir fail-safe operation uses the appropriate Easytork control arrangement.
Catalogue mounting summary → · EVA-0411 interface drawing → · EVA-1646 interface drawing →
Choose the Easytork control interface for the duty
Matched accessories connect the same reservoir fail-safe principle to different control requirements. Select the control role first, then confirm its physical and pneumatic connections.
ESV, EPV and NTV roles
- ESV: a 5/2 solenoid valve at its core, providing the Easytork electrical on/off control arrangement.
- EPV: a 5/2 pilot valve at its core, interfacing any non-NAMUR-mount third-party 3/2 solenoid valve with Easytork fail-safe actuation.
- NTV: a universal device for double-acting positioners, adding Easytork’s reservoir fail-safe function to modulating duty.
Functionally compatible accessories can still require different mounting hardware or pneumatic connections. Follow the selected actuator and control arrangement’s mounting and piping instructions.
The installation orientation of ESV, EPV or NTV determines clockwise or counter-clockwise actuator fail action. Which direction means valve-open or valve-closed depends on the valve design and installation.
Make the connection review specific
Provide the actuator model, accessory manufacturer and model, mounting drawing, supply pressure, signal type and intended fail response. This separates a mechanical mounting question from a control-function question and avoids treating either as a complete assembly approval.
Read the port-by-port control explanations → · Review the process-valve mounting interface →
Technical references
Contact us about the handbook →
Catalogue interface and accessory specifications · Model-specific drawings
Work through your application
Send the actuator and accessory models or drawings. We can help resolve the mounting, connection and control requirements.
Contact us →