Home/K-TORK torque comparison
EXISTING VANE ACTUATOR?

Compare the torque.
See the nearby sizes.

Find the Easytork sizes immediately below and above a K-TORK model’s published torque at the same pressure.

This is a torque comparison, not a recommended replacement. Choose the actuator for your valve application, including the torque profile, safety factor, mounting, controls and service conditions.

← Back to replacement planning
Operating action
Units

Fail-safe torque comparison

K-TORK spring-return end torque is compared with Easytork stored-air minimum end-of-stroke torque. Understand spring configuration and charged-supply pressure → Spring configuration: 80 psi balance.

On a phone, swipe the table sideways. The K-TORK model stays visible.

Fail-safe torque comparison · 80 psi · in-lb
K-TORK modelK-TORK spring end
End-of-stroke torque
Nearest EVA below
Fail-safe end-of-stroke
Nearest EVA above
Fail-safe end-of-stroke
KT-02-Not published in this tableUnavailableUnavailable
KT-0373 in-lbNo published size belowEVA-0411219 in-lb+200% vs K-TORK
KT-06144 in-lbNo published size belowEVA-0411219 in-lb+52.1% vs K-TORK
KT-10410 in-lbEVA-0411219 in-lb-46.6% vs K-TORKEVA-0514420 in-lb+2.4% vs K-TORK
KT-20800 in-lbEVA-0514420 in-lb-47.5% vs K-TORKEVA-0717983 in-lb+22.9% vs K-TORK
KT-301,790 in-lbEVA-0717983 in-lb-45.1% vs K-TORKEVA-10221,963 in-lb+9.7% vs K-TORK
KT-403,762 in-lbEVA-10221,963 in-lb-47.8% vs K-TORKEVA-12274,127 in-lb+9.7% vs K-TORK
KT-50-Not published in this tableUnavailableUnavailable
KT-60-Not published in this tableUnavailableUnavailable

Need to review a specific installation?

Plan a vane actuator replacement →

Bring the full model number, air pressure, valve torque requirements and mounting details.

Discuss your application →View the complete EVA torque tables →